their maximum capacity. When reaching their full capacity the red light on the
charger will not light any more.
When they are ready pull the device out of the electric net and unplug the jack
out of the ―CHARGE‖
NOTE: Don’t unplug the charger if charge pr ocess is n ot finished.
Always charge device's storage batteries ONLY with the paired chargers to
it. Thus y ou w ill prevent da mages or confusion between “+” and “ -” because
the use of other chargers or adaptors may lead to irretrievable damages in
the batteries!
8. Possible problems during exploitation of Delta4:
1.When switching it on you can not hear a sound, no indication that the
device is switched on. It might indicate for:
-storage batteries are dead (usually after a long period of time). Charge the
batteries with the charger. If the problem is not solved contact the service-
station (office) of the company manufacturer or the local distributor.
-the accumulator block consists of 10 elements 1,2V / 1000mAh (or 2700mAh)
connected in series. If just one of them is damaged the connection between
them will be destroyed and practically the device will be left without power
supply.
2. The working depth is significantly shallower than the normal. It might
indicate for:
- storage batteries could be dead – charge the batteries with the automatic
charger. If you can not solve the problem contact the service-station (office) of
the company manufacturer or the local distributor.
3.During detection the device does not work stable, makes strange sounds
which are not due to a metal detection. It might indicate for:
-irregular electromagnetic external interruptions.
-problems with the aerial cable – disconnected conductor, a shot circuit or bad
connection in the coupling.